Storage, Backup and Hyperconverged

Connection reference for 46 array, backup, and hyperconverged collectors.

Arrays, backup platforms, and hyperconverged systems. See Supported Devices for how to read these entries.

Cohesity

Cohesity Backup

FieldValue
Device typeCOHESITY_BACKUP
User role“Viewer”
Default ports443
Collection methodAPI
Required parametersIP: IP address of any node, or DNS name of the cluster
User: user name
Password
Domain: the user’s domain, for example company.com or LOCAL
API Token: cluster API key, an optional replacement for User and Password
NotesRequires the Cohesity Management SDK, installed separately on the data collection machine: pip install cohesity-management-sdk

Cohesity Helios

FieldValue
Device typeCOHESITY_HELIOS_DEVICE
User roleHelios API key with access to the target cluster
Default ports443
Collection methodAPI, via the Cohesity Helios cloud broker
Required parametersPassword: Helios API key, not the cluster’s own password
IP: not a network address. Enter the target cluster’s Helios Cluster ID
Optional parametersUser: not used by this collector, leave blank
NotesAn alternative connectivity path to the Cohesity Backup collector above, for clusters managed through Cohesity’s Helios cloud control plane rather than reachable directly on their own IP.

Cohesity Helios SaaS

FieldValue
Device typeCOHESITY_HELIOS_SAAS_DEVICE
User roleHelios API key
Default ports443
Collection methodAPI, via the Cohesity Helios cloud (SaaS only, no on-premise cluster)
Required parametersPassword: Helios API key
Optional parametersUser: not used by this collector, leave blank
NotesCollects FortKnox vault and Microsoft 365 backup job data only. It does not duplicate the per-cluster job, policy, or inventory data already collected by the Cohesity Backup or Cohesity Helios collectors.

NetBackup

FieldValue
Device typeNETBACKUP_BACKUP
User role“NetBackup Read-Only Operator”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
API Token
NotesGenerate the API token under Access Keys, then API Keys.

Commvault

Commvault Backup

FieldValue
Device typeCOMMVAULT_BACKUP
User roleRole with global “View” and Commcell “Use Commcell” privileges
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
NotesOn some Commvault versions “Use Commcell” is not available as an option. Where that is the case, the requirement can be disregarded.

Dell EMC

Compellent

FieldValue
Device typeCOMPELLENT_DEVICE
User role“Reporter”
Default ports3033
Collection methodAPI
Required parametersIP: IP address or DNS name for Storage Center
User: user name
Password
Serial Number: serial number of the array
NotesContact Visual One before deploying this collector, as it may require adjustments for your environment.

Data Domain

FieldValue
Device typeDATA_DOMAIN
User role“User”
Default ports22
Collection methodSSH/CLI
Required parametersIP: IP address or DNS name
User: user name
Password

Elastic Cloud Storage (ECS)

FieldValue
Device typeECS_DEVICE
User roleAny user with read-only access or higher
Default ports4443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

Isilon / PowerScale

FieldValue
Device typeISILON_DEVICE, POWERSCALE_DEVICE
User roleCopy “Statistics Admin” and add read access to Cluster, NFS, and SMB
Default ports8080
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

PowerStore

FieldValue
Device typePOWERSTORE_DEVICE
User role“Operator”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

ScaleIO

FieldValue
Device typeSCALEIO_DEVICE
User role“Monitor”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
NotesContact Visual One before deploying this collector, as it may require adjustments for your environment.

Unity

FieldValue
Device typeTEST_UNITY_DEVICE
User role“Operator”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

VMAX / PowerMax

FieldValue
Device typeTEST_VMAX_DEVICE, POWERMAX_DEVICE
User role“PerfMonitor”
Default ports8443
Collection methodAPI
Required parametersIP: IP address or DNS name for Unisphere
User: user name
Password
Serial Number: Symmetrix ID of the array
NotesRequires Unisphere 10.2 or higher.

VNX

FieldValue
Device typeVNX_DEVICE
User role“Operator” with CLI access is sufficient for utilization and configuration data. Root access is required to also collect performance data.
Default ports443, 8443
Collection methodCLI
Required parametersIP: IP address or DNS name
User: user name
Password
CLI Path: path where navisseccli.exe is installed
NotesRequires the EMC Navisphere Command Line Interface installed on the data collection machine.

VPLEX

FieldValue
Device typeVPLEX_DEVICE
User role“readonly”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
NotesContact Visual One before deploying this collector, as it may require adjustments for your environment.

XtremIO

FieldValue
Device typeXTREMIO_DEVICE
User role“read-only”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
Optional parametersArray Name: cluster name, if more than one exists in a single management console

Hitachi Vantara

Ops Center (VSP)

FieldValue
Device typeHITACHI_OPS_DEVICE
User roleRead-only user created in Ops Center
Default ports443, 8443, 20961
Collection methodAPI
Required parametersIP: IP address or DNS name for Ops Center Common Services
User: Ops Center user name
Password
Serial Number: serial number of a storage system

VSP 360

FieldValue
Device typeHITACHI_VSP360_DEVICE
User roleOAuth2 client credential pair (Client ID and Client Secret) registered on the VSP 360 appliance
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name of the VSP 360 appliance
User: OAuth2 Client ID
Password: OAuth2 Client Secret
Serial Number: scopes collection to one array at a time
Optional parametersPort, default 443
NotesFor Hitachi’s newer converged management appliance, which bundles Administrator, Analyzer, and Configuration Manager.

HNAS

FieldValue
Device typeHITACHI_HNAS_API_DEVICE (primary, preferred)
HITACHI_HNAS_DEVICE (alternate, legacy)
User roleAPI: a read-only API key, created over SSH to the HNAS node using apikey-create, then apikey-update to strip the default full-access scope and grant native-rest-read only. The key text is shown once, at creation.
SSH/CLI alternate: “user” is sufficient for basic capacity data, “supervisor” is required for detailed volume data. It must be created at the cluster level rather than the SMU, using user add <name> <password> user. This is the only way to create a read-only user with CLI access.
Default ports8444 (alternate: 22)
Collection methodAPI (alternate: SSH/CLI)
Required parametersIP: IP address or DNS name of an HNAS node, not the SMU. Only one node per cluster is needed to retrieve data for all of them.
Password: for the API collector this holds the API key rather than a device password
User: required for the SSH/CLI alternate, not used by the API collector
Optional parametersPort
NotesThe API collector probes API version 8 first, which requires NAS OS 14.5 or later, then falls back to version 7.

HCP

FieldValue
Device typeHITACHI_HCP_DEVICE
User role“Monitor”
Default ports9090
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
NotesThe user must be added under each tenant, and the management API must be enabled under security settings.

HPE

3PAR

FieldValue
Device typeTHREE_PAR_DEVICE
User role“Browse”
Default ports8080
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
Port: HTTPS port, default 8080
NotesVerify the StoreServ WSAPI server is running with the CLI command showwsapi. Confirm HTTPS is enabled and that the correct HTTPS port is set in Visual One. Enable the WSAPI server and HTTPS with startwsapi and setwsapi -https enable.

Alletra 9000 Series

FieldValue
Device typeHP_ALLETRA_DEVICE
User role“Browse”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
NotesFor Alletra 9000 Series arrays, which are based on 3PAR architecture.

Alletra 5000/6000 Series

FieldValue
Device typeNIMBLE_ALLETRA_DEVICE
User role“Guest”
Default ports443, 5392
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
NotesFor Alletra 5000 and 6000 Series arrays, which are based on Nimble architecture.

Primera

FieldValue
Device typeHP_PRIMERA_DEVICE
User role“Browse”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

Nimble

FieldValue
Device typeNIMBLE_DEVICE
User role“Guest”
Default ports443, 5392
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

StoreOnce

FieldValue
Device typeHP_STOREONCE_API_DEVICE (primary)
HP_STOREONCE_DEVICE (alternate, for older arrays)
User role“Observer”
Default ports443 (alternate: 22)
Collection methodAPI (alternate: SSH/CLI)
Required parametersIP: IP address or DNS name
User: user name
Password
NotesNewer arrays with no CLI support must use the API collector.

IBM

DS8000

FieldValue
Device typeDS8K_DEVICE
User role“Monitor”
Default ports1751, 22
Collection methodIBM DSCLI
Required parametersIP: IP address or DNS name
User: user name
Password
NotesRequires IBM DSCLI installed on the data collection server. The directory containing dscli.exe must be added to the system PATH.

FlashSystem / Storwize / SVC

FieldValue
Device typeIBM_FLASH_SYSTEM (primary, preferred, covers all models below)
IBM7200_DEVICE, IBM9100_DEVICE, IBM9200_DEVICE, IBM9500_DEVICE, SVC_DEVICE, V7000_DEVICE, V9000_DEVICE, FLASH900_DEVICE (alternate, legacy)
User role“Monitor” for both methods
Default ports7443 (alternate: 22)
Collection methodAPI (alternate: SSH/CLI)
Required parametersIP: IP address or DNS name
User: user name
Password
NotesThe legacy device types share one underlying SSH/CLI collector, so choose whichever matches your device most closely. That choice only affects how the device is displayed in Visual One.

Spectrum Protect / TSM

FieldValue
Device typeTSM_BACKUP
User role“Self Service”
Default ports1500
Collection methodTSM Administrative CLI (dsmadmc)
Required parametersIP: IP address or DNS name
User: user name
Password
Port: TCP port, default 1500
CLI Path: path to dsmadmc.exe
NotesRequires TSM Administrative Tools (dsmadmc) installed on the data collection machine.

Infinidat

InfiniBox

FieldValue
Device typeINFINIDAT_DEVICE
User role“READ_ONLY”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
Optional parametersInfinimetrics IP: needed for performance metrics

NetApp

C-Mode (Clustered Data ONTAP)

FieldValue
Device typeNETAPP_CLUSTER_API (primary, preferred)
NETAPP_CLUSTER (alternate, legacy)
User role“readonly”
Default ports443 (alternate: 22)
Collection methodAPI (alternate: SSH/CLI)
Required parametersIP: IP address or DNS name
User: user name
Password
Optional parametersPort
NotesThe API collector uses ONTAP’s REST API for ONTAP 9.6 and later. NetApp Cloud Volumes ONTAP is also supported and requires no additional configuration.

7-Mode (Data ONTAP 7-Mode)

FieldValue
Device typeNETAPP_DEVICE
User roleAdministrator role, required for CLI access
Default ports22
Collection methodCLI/SSH
Required parametersIP: IP addresses or DNS names, comma separated with no spaces, for example NetApp01,NetApp02
User: user name
Password
NotesSpecify one IP address or DNS name per node.

E-Series

FieldValue
Device typeESERIES_DEVICE
User role“Monitor”
Default ports2044, 8443
Collection methodSANtricity Secure CLI (SMcli)
Required parametersIP: IP address or DNS name
User: user name
Password
NotesRequires SANtricity Storage Manager installed on the data collection machine, with the path to smcli.exe in the PATH environment variable.

Nutanix

Nutanix / Prism

FieldValue
Device typeNUTANIX_V4_DEVICE (primary, preferred, Prism Central v4)
NUTANIX_DEVICE (alternate, legacy, Prism v0.8 to v3)
User role“Prism Viewer”
Default ports9440, 443
Collection methodAPI
Required parametersIP: IP address or DNS name of Prism Central
User: user name
Password
Optional parametersPort
NotesNUTANIX_V4_DEVICE replaces the older v0.8 to v3 collector and is the preferred method for new deployments. The legacy collector remains available for compatibility. A single collection reports the Nutanix cluster both as a storage device and as its hypervisor, ESXi or AHV, including cluster, host, datastore, and VM detail. If a vCenter runs entirely on Nutanix, a separate VMware collection is not needed. If a vCenter spans Nutanix and other hardware, consult Visual One staff to avoid duplicate reporting.

Oracle

Exadata

FieldValue
Device typeORACLE_EXADATA
User roleCell Monitor, or equivalent, on one compute node and all storage cells, with host equivalence configured so that an authenticated session on the compute node can reach the storage cells without re-authenticating.
Default ports22
Collection methodSSH/CLI
Required parametersIP: IP address of the compute node
User: user name
Password
Cells: comma separated storage cell IPs
NotesRequires additional configuration, including a shell script and an ASM instance query. Consult Visual One staff for support.

ZFS

FieldValue
Device typeZFS_DEVICE
User roleAny role with read-only access or higher
Default ports22
Collection methodSSH/CLI
Required parametersIP: IP address or DNS name
User: user name
Password

Pure

FlashArray

FieldValue
Device typePURE_DEVICE
User role“readonly”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
Optional parametersAPI Token
NotesFor FlashArrays with unified file storage enabled, an API token is required to collect file system utilization data. Generate it on the FlashArray’s user management screen.

FlashBlade

FieldValue
Device typeFLASHBLADE_DEVICE
User role“readonly”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
API Token
NotesGenerate the API token on the FlashBlade’s user management screen.

Qumulo

Qumulo Core

FieldValue
Device typeQUMULO_DEVICE
User role“Observer”
Default ports443, 8000
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

Rubrik

Rubrik Security Cloud

FieldValue
Device typeRUBRIK_RSC_DEVICE
User roleService account with permission to view all resources
Default ports443
Collection methodAPI
Required parametersIP: <IP>.my.rubrik.com
User: client_id, including the “client|” prefix
Password: client_secret
Cluster UUID: from Cluster Details
NotesPreferred over the legacy CDM collector. For the service account role, start from the built-in “Auditor” template, then update its “Assign System Configuration Privileges” and “Rubrik Application Privileges” settings to include all view privileges.

Rubrik CDM (legacy)

FieldValue
Device typeRUBRIK_BACKUP
User role“Read-Only Administrator” service account, created in CDM
Default ports443
Collection methodAPI
Required parametersUser: service user ID, which should include the “User:::” prefix
Password: the service user’s secret, added as an SSH key in Visual One
IP: IP address or DNS name
NotesIn Visual One, choose the “use SSH key instead of password” option and store the service account secret there.

Scality

RING

FieldValue
Device typeSCALITY_DEVICE
User roleRead only
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name of the Supervisor
User: user name
Password

Silk

Silk Cloud Data Platform

FieldValue
Device typeSILK_DEVICE
User roleRead-only
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password
NotesReports as a “storage device” in Visual One.

Synology

DiskStation Manager

FieldValue
Device typeSYNOLOGY_DEVICE
User roleRead-only user with REST API privilege
Default ports5001
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

Tintri

VMstore

FieldValue
Device typeTINTRI_DEVICE
User role“Read Only”
Default ports443
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

Veeam

Veeam Backup

FieldValue
Device typeVEEAM_BACKUP
User role“Veeam Backup Viewer”
Default ports9419
Collection methodAPI
Required parametersIP: IP address or DNS name
User: user name
Password

Last updated: September 3, 2026